10000 W SANTA MONICA BLVD 90067
APPLICATION / PERMIT NUMBER: 13030-10000-00842
PLAN CHECK / JOB NUMBER: B13LA02209

Plan Check and Permit Information


GROUP: Building
TYPE: Grading
SUB-TYPE: Apartment
PRIMARY USE: (70) Grading - Hillside
WORK DESCRIPTION: PROPOSED SITE PREP, BASEMENT EXCAVATION AND RETAINING WALL BACKFILL FOR A HIGHRISE BLDG WITH 2 BASEMENT LEVELS BEING ISSUED UNDER 12010-10000-01522 PROPOSED EXCAVATION FOR SHORING AND BASEMENT. CUBIC YARDS OF CUT IS 29,366 CUBIC YARDS (INCLUDES 12330 OF R/R), 19,004 CUBIC YARDS OF FILL (INCLUDES 12330 CUBIC YARDS OF R/R), AND A TOTAL OF 10,362 CUBIC YARDS OF EXPORT. SEE CLEARANCE SUMMARY SHEET FOR SHORING IN PERMIT 13020-10000-00385. THE HIGHRISE BLDG WITH 2 BASEMENT LEVELS IS BEING ISSUED UNDER 12010-10000-01522 SEE COMMENTS
PERMIT ISSUED: Yes PERMIT ISSUE DATE: 12/03/2013 ISSUING OFFICE: Metro
CURRENT STATUS: Permit Finaled CURRENT STATUS DATE: 11/21/2016

Permit Application Status History
Submitted 02/28/2013 APPLICANT
Assigned to Plan Check Engineer 02/28/2013 JOHN VASQUEZ
Corrections Issued 03/11/2013 JOHN VASQUEZ
Quality Review Completed 03/11/2013 CHARLES CHANG
Building Plans Picked Up 03/12/2013 APPLICANT
Applicant returned to address corrections 05/31/2013 JOHN VASQUEZ
Applicant returned to address corrections 09/30/2013 JOHN VASQUEZ
Plan Check Approved 12/03/2013 JOHN VASQUEZ
Issued 12/03/2013 LADBS
Permit Finaled 11/18/2016 AL GAMBLE

Permit Application Clearance Information
Miscellaneous Cleared 09/26/2013 JACK CHIANG

Licensed Professional/Contractor Information
Contractor Information
Owner-Builder
  
Engineer Information
Burnett, Larry Alan; Lic. No.: C36209
1232 SOUTH FIFTH ST
ALHAMBRA, CA  91801
Engineer Information
Spindler, Ronald W; Lic. No.: C13194
16823 SATICOY STREET
VAN NUYS, CA  91406

Inspection Activity Information

Inspector Information
RUSSELL BONVOULOIR, (310) 914-3932
Office Hours: 7:00-8:00 AM MON-FRI
MATTHEW JENKINS, (310) 914-3932
Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspection Request(s)
  No data available

Inspection Request History
  Initial Grading   03/12/2014   Approved   GAYK MANUKYAN
  Deputy Other (see comments)   05/01/2014   No Access for Inspection   GAYK MANUKYAN
  Deputy Grading   05/14/2014   Conditional Approval   GAYK MANUKYAN
  Deputy Grading   05/15/2014   No Access for Inspection   GAYK MANUKYAN
  Bottom/Toe   05/16/2014   Corrections Issued   GAYK MANUKYAN
  Deputy Grading   05/16/2014   Approved   GAYK MANUKYAN
  SWPPP-Const. Storm Water   05/16/2014   Completed   GAYK MANUKYAN
  Bottom/Toe   05/22/2014   Partial Approval   GAYK MANUKYAN
  Fill/Backfill   05/23/2014   Partial Inspection   SERGIO VALENZUELA
  Bottom/Toe   05/28/2014   Partial Approval   GAYK MANUKYAN
  Fill/Backfill   05/28/2014   Partial Inspection   GAYK MANUKYAN
  Bottom/Toe   06/02/2014   Partial Inspection   GAYK MANUKYAN
  Fill/Backfill   06/02/2014   Partial Inspection   GAYK MANUKYAN
  Fill/Backfill   06/13/2014   Partial Inspection   GAYK MANUKYAN
  Bottom/Toe   06/25/2014   Partial Approval   GAYK MANUKYAN
  Bottom/Toe   06/30/2014   Partial Approval   GAYK MANUKYAN
  Fill/Backfill   08/04/2014   Partial Inspection   GAYK MANUKYAN
  Approved Compaction Report   08/05/2014   Approved   GAYK MANUKYAN
  Sub-Drain   09/26/2014   Partial Approval   GAYK MANUKYAN
  Sub-Drain   10/01/2014   Partial Approval   GAYK MANUKYAN
  Sub-Drain   10/24/2014   Partial Approval   GAYK MANUKYAN
  Drainage Devices/Catch Basin   04/23/2015   Partial Approval   TIMOTHY POWELL
  Sub-Drain   05/29/2015   Partial Approval   TIMOTHY POWELL
  Sub-Drain   06/01/2015   Partial Approval   TIMOTHY POWELL
  Sub-Drain   06/02/2015   Partial Approval   TIMOTHY POWELL
  Sub-Drain   09/10/2015   Partial Approval   AL GAMBLE
  Bottom/Toe   02/29/2016   Not Ready for Inspection   AL GAMBLE
  METHANE-Rough   02/29/2016   Off-Hour Fees Due   
  Rough   02/29/2016   Off-Hour Fees Due   
  Rough   02/29/2016   Partial Inspection   AL GAMBLE
  SWPPP-Const. Storm Water   02/29/2016   Off-Hour Fees Due   
  Rough   03/04/2016   Partial Approval   AL GAMBLE
  SWPPP-Const. Storm Water   03/04/2016   Not Required   AL GAMBLE
  Rough   03/10/2016   Partial Inspection   AL GAMBLE
  Rough   03/17/2016   Not Ready for Inspection   AL GAMBLE
  Rough   03/21/2016   Partial Approval   AL GAMBLE
  Drainage Devices/Catch Basin   04/18/2016   Partial Approval   BRIAN OLSON
  Bottom/Toe   04/27/2016   Partial Approval   AL GAMBLE
  Fill/Backfill   04/27/2016   Not Ready for Inspection   AL GAMBLE
  Rough   05/04/2016   Not Ready for Inspection   AL GAMBLE
  Drainage Devices/Catch Basin   05/25/2016   Partial Inspection   TIMOTHY POWELL
  Drainage Devices/Catch Basin   05/26/2016   Partial Approval   TIMOTHY POWELL
  Drainage Devices/Catch Basin   06/01/2016   Not Ready for Inspection   AL GAMBLE
  Drainage Devices/Catch Basin   06/03/2016   Partial Approval   AL GAMBLE
  Irrigation/Landscape   06/03/2016   Partial Inspection   AL GAMBLE
  Drainage Devices/Catch Basin   07/21/2016   Partial Approval   AL GAMBLE
  Drainage Devices/Catch Basin   07/28/2016   Partial Approval   AL GAMBLE
  Drainage Devices/Catch Basin   08/01/2016   Partial Approval   AL GAMBLE
  Irrigation/Landscape   08/01/2016   Not Ready for Inspection   AL GAMBLE
  Approved Compaction Report   08/04/2016   Approved   AL GAMBLE
  SWPPP-Const. Storm Water   10/14/2016   Not Required   JEFFREY DURAN
  Bottom/Toe   10/18/2016   Not Ready for Inspection   AL GAMBLE
  Final   10/18/2016   Not Ready for Inspection   AL GAMBLE
  Rough   10/18/2016   Not Ready for Inspection   AL GAMBLE
  SUSMP-Std. Urban Storm Water   10/18/2016   Not Ready for Inspection   AL GAMBLE
  Sub-Drain   10/20/2016   Partial Inspection   AL GAMBLE
  Excavation   10/21/2016   Partial Approval   AL GAMBLE
  Drainage Devices/Catch Basin   10/27/2016   Not Ready for Inspection   AL GAMBLE
  Bottom/Toe   11/18/2016   Approved   AL GAMBLE
  Final   11/18/2016   Permit Finaled   AL GAMBLE
  Rough   11/18/2016   Approved   AL GAMBLE